ARGYNET LABSolutionsInternal walls & partitionsSound insulation of partition walls using dry construction
Back to Solutions
Sound insulation of partition walls using dry construction
Internal walls & partitions

Sound insulation of partition walls using dry construction

Last updated:

Sound insulation of partition walls using dry construction: mass, stone wool, decoupling and sealing. New wall or loose cladding of an existing wall, with layer

The system at a glance

Solutions & Applications · Sound insulation

Sound insulation of a partition wall — whether existing or new — does not require thick brickwork. A properly designed dry construction wall achieves higher sound reduction than a conventional brick wall twice as thick, provided that four factors are combined: mass, absorption, decoupling and airtightness. If one is missing, the construction fails.

New or existing partition wall?

Case studySolutionWhat determines the outcome
New partition between flats or officesDry construction wall with a CW 75 or 100 frame, stone wool and a double board on each sideSlab mass, full void, track
Very high standard (studio, meeting room, doctor’s surgery)Double independent frame or double slab with ISOLFON BARRIERComplete separation of the two sides
Existing brick partition wallFree-standing cladding in front of the wall: self-supporting framework, cavity, stone wool, double slabThe new framework must not rest against the old wall

On an existing partition wall, bonding plasterboard cladding does not help — it often worsens the acoustics at speech frequencies. The explanation lies in the ‘Dry Construction Wall Cladding’ solution.

The principle: mass – spring – mass

A dry construction wall functions acoustically as a mass–spring–mass system. The panels on either side are the masses, whilst the stone wool in the cavity acts as the spring that dampens the energy. If the cavity is empty or the two sides are rigidly connected, the sound finds a path — however good the board may be.

That is why a ‘thick’ wall is not necessarily quiet — whereas a thin, properly designed one can be.

The 4 parameters

  1. Mass: the right board. A standard plasterboard is rarely sufficient. Knauf SILENTBOARD DFR has a high-mass core (~17.9 kg/m² at 12.5 mm) and excels at low frequencies — bass, machinery, speech. Alternatively, Piano DF or DIAMANT DFH1IR. Double layer on each side, with offset joints.
  2. Absorption: complete void filling. FIBRANgeo B-050 stone wool (αw 1.00, A1) fills the entire void — without gaps and without compression, because when compressed it ceases to act as a spring.
  3. Decoupling: no rigid bridges. Track tape on the back of each UW, on floors, ceilings and walls. For maximum performance, the viscoelastic ISOLFON BARRIER membrane (EPDM 3.5 / 5 / 10 kg/m², asphalt-free) is inserted between the two slabs to dampen low-frequency noise.
  4. Waterproofing: sound passes through wherever air passes. Sealing of the perimeter, floor and ceiling finishes, penetrations and electrical boxes. An unsealed joint just a few millimetres wide can negate an otherwise precise construction.

Layering as required

LevelFramework & spacingSlabs per side
Basic — offices, roomsCW 75 · stone wool · track tape1 × Piano DF
Reinforced — partition wallsCW 75 or 100 · stone wool · track membrane2 × SILENTBOARD or DIAMANT
High — studios, doctors’ surgeries, meeting roomsCW 75 or 100 or double framework; stone wool2 slabs with ISOLFON BARRIER in between
Existing wallCW/UW loose-fill insulation with air gap; stone wool2 slabs, with or without BARRIER

For example, according to the ISOLFON documentation: a plasterboard wall with a metal framework, mineral wool and BARRIER 5 between two layers of plasterboard on each side achieves Rw(C;Ctr) = 56(-4;-11) dB; masonry with plasterboard cladding and BARRIER achieves Rw = 60 dB.

ARGYNET Note

The most common mistake is not the choice of board — it is acoustic ‘short circuits’: electrical boxes back-to-back in the same cavity, unsealed perimeter ends, a shared track without elastic tape, and a cladding frame that rests against the old wall.

Sound insulation does not stop at the wall. If the noise is impact-related — footsteps, knocks from the floor above — work needs to be carried out on the floor, using a floating floor in ISOLFON ReRub.

At ARGYNET, we design the layering according to the required level of sound insulation and calculate materials per m². The Rw value is always taken from the system’s certified data sheet — not from the sum of the individual materials.

Mistakes that cost

IncorrectConsistency
Empty shellThe gap acts as a resonator and may amplify the noise
Compressed stone woolIt loses its elasticity; it ceases to act as a spring
Aligned joints in the double layerA seamless journey for sound
Socket boxes positioned opposite each other in the same locationA hole in the structure — sound passes through it
Without track tapeLateral transmission from floor and ceiling
Adhesive cladding on an existing partition wallSame or poorer acoustics

High-Density Slabs

Absorption & Disconnection

Framework

Related Solutions from ARGYNET LAB

Do you want a partition wall that really stops noise? Tell us what you can hear.

Request a Technical Quotation

Need a materials proposal for your project?