Fire protection of structures
Last updated:
Reaction to fire or fire resistance? What do A1, A2-s1,d0 and EI mean? Why does stone wool not have an EI rating? Where is the fire resistance lost, and what do
The system at a glance
- FIBRANgeo B-050 | Stone wool for masonry, roofing and dry construction
- FIBRANgeo B-001 | Stone wool for masonry, roofing and dry construction
- ULTRACOUSTIC P | Mineral wool boards
- FIBRANgeo BP-ETICS | Stone wool for External Thermal Insulation
- KNAUF (DF) 12.5 mm | Fire-rated plasterboard
- DIAMANT DFH1IR 12.5mm | High-performance plasterboard
- KNAUF ULTRA BOARD 15mm | Special fire-rated DFIR plasterboard
- KNAUF FIREBOARD 12.5mm | Class A1 fireboard
- Knauf CW stud 50x50x0.6 mm
- Knauf UW track 50x40x0.6 mm
- KNAUF Fugenfüller Leicht
- F-TEC F90 Fire-Rated Access Panel
- TEKTALAN A2-HS | Wood wool with stone wool core
- HERAKLITH A2-C | Wood-fibre boards
- AQUAPANEL® Indoor cement board
Solutions & Applications · Fire Protection & Insulation
Stone wool is ‘born of fire’ — produced by melting rock at approximately 1,520 °C — and is therefore non-combustible. However, this does not make the building fire-rated. Fire protection has two distinct aspects, and confusion between them is the cause of most errors in the design.
The two sizes
| Reaction to fire | Fire resistance | |
|---|---|---|
| Standard | EN 13501-1 | EN 13501-2 |
| What matters | How much does a material contribute to a fire? | How long does a structural element continue to function? |
| Applies to | The material | The system — wall, ceiling, door |
| Classification | A1, A2, B, C, D, E, F | R, E, I — e.g. EI 30 / EI 60 / EI 90 / EI 120 |
| Example | Stone wool: A1 | Partition wall with stone wool and fire-rated plasterboard: EI 90 |
The letters denoting resistance are defined as follows: R is the load-bearing capacity, E is integrity — the element does not allow the passage of flame or hot gases — and I is thermal insulation performance, meaning that the unexposed side does not reach a dangerously high temperature. An EI 90 partition maintains both properties for ninety minutes.
No stone wool board has an EI rating. It is the partition that has the EI rating. This is the most common misunderstanding in specifications and quotations — and leads to projects that ‘have the right materials’ but do not comply with the design.
Fire resistance is certified by testing the entire assembly: type and thickness of plasterboard, number of layers, profile and spacing of studs, density and thickness of stone wool, and method of jointing. If any of these are changed, the certification is no longer valid — however ‘equivalent’ the substitute may be.
The question in the tender is not ‘is the stone wool A1?’ but ‘which certified system provides the required EI rating and what is its exact composition?’. The step-by-step installation and inspection of such a system are set out in the EI 90 fire-rated partition solution.
The classification of the material, letter by letter
| Classification | What does this mean? | Standard materials |
|---|---|---|
| A1 | Non-combustible — makes no contribution to a fire | Stone wool, mineral wool, cement board, FIREBOARD fire-resistant board |
| A2 | Practically non-combustible, with very low organic content | Plasterboard, wood wool with a mineral binder |
| B to E | Increasing contribution to the fire | Foam insulation — XPS is classified as E |
The following indicators are equally important and are often overlooked:
- s1, s2, s3 — smoke production. In building fires, smoke kills before the flame does: it reduces visibility in escape routes to zero and hinders rescue operations. s1 represents the lowest level of smoke production.
- d0, d1, d2 — flaming droplets. d0 means none. Drips carry the fire downwards and ignite secondary fires — which is why they are particularly important in garage ceilings and on façades.
An A2-s1,d0 is therefore practically non-combustible, with minimal smoke and no droplets — and is not to be confused with A1, which contains no organic material whatsoever.
Protection of the load-bearing structure
It is the argument that does not concern people’s lives but the cost of restoration — and often determines the decision.
As early as ~270 °C, the bond between concrete and steel begins to deteriorate and cracks appear. As the temperature rises, the moisture within the concrete turns to steam; the pressure cannot be released quickly enough and the surface flakes off in sheets, exposing the reinforcement. The exposed steel rapidly loses its strength.
A layer of non-combustible material between the fire and the load-bearing element delays the transfer of heat. It does not protect the contents — it protects the structural integrity, and in doing so prevents the need for repairs using epoxy resins and carbon fibres, which cost many times more than the original insulation. On metal structures, the cladding is made of A1-grade fireboard.
The most common way for a fire-rated element to be invalidated
It’s not the material. It’s the penetrations. An EI 120 partition with an unsealed cable penetration is not EI 120 — it’s a partition with a hole in it.
| Point | The right solution |
|---|---|
| Cable and pipework penetrations | Certified fire barrier systems, of the same class as the partition — standard foam is not a fire barrier |
| Ventilation ducts | Fire barriers at penetration points — insulation around the air duct is not sufficient |
| Connection to the slab | Top-end sealing that allows the slab to move without creating a gap |
| Switch boxes | Do not place them back-to-back within the same opening |
| Access hatches | Of the same class as the wall, e.g. F-TEC F90 |
| Grouting | Complete filling of joints — an open joint acts as a passage for hot gases |
The rule is simple: the fire resistance of a component is equal to that of its weakest point.
Where it is used
| Position | Solution | What else it offers |
|---|---|---|
| Fire-rated dry construction partitions | Stone wool core + fire-rated plasterboard on a metal frame | Sound insulation and thermal insulation in the same thickness |
| Lining of metal structures, shafts and high-risk areas | FIREBOARD A1 fire-resistant board | Non-combustible surface, not just fire resistance |
| Garage and entrance hall ceilings | Wood-woolle or composite board with a stone wool core | Sound absorption and visible natural surface |
| External wall insulation with foam insulation | Fire barriers with stone wool strips | — |
| External wall insulation made entirely of stone wool | Non-combustible system across the entire façade | Fire barriers are being removed — one detail instead of many |
What the regulations require
Under the current fire safety regulations (Presidential Decree 41/2018), non-combustible insulation materials in cladding are required in buildings adjacent to boundaries or to another building, school premises, hospitals, venues accommodating more than 1,000 people and high-rise buildings over 23 m. From 2023, this requirement will be extended, under the Fire Protection Regulations for Properties, to include properties situated within or near woodland areas.
In practice, this requirement is the first to be checked in a thermal insulation design: if it is present, it determines the material, and everything else — thickness, render, colour — follows.
All three sizes together
Stone wool is not chosen solely for fire resistance. At the same thickness, it provides thermal insulation with λ ≈ 0.035 W/mK, vapour permeability with μ ≈ 1 — practically the same resistance as still air — and sound absorption, thanks to its open-fibre structure which converts sound energy into friction. It is one of the few materials where regulatory requirements and user benefits coincide.
Stone wool & mineral wool
Fire-rated Partitions & Cladding
Ceilings, Cladding & Wet Areas
Related Solutions from ARGYNET LAB
The design brief specifies EI — which certified system provides this?
Request a Technical Quotation