Concrete on the Islands: New Build, Repair and Strengthening by the Sea
Last updated:
New build, repair and strengthening of concrete by the sea: VANDEX, SINTOCRETE, MuCis and S&P carbon fibre as one system, delivered in one shipment.
The system at a glance
- TECNOS 95 | Concrete Superplasticiser with Retarding Effect
- VANDEX AM 10 | Crystalline Waterproofing Admixture for Concrete
- MuCis ad 19/L | Contact and Migrating Corrosion Inhibitor for Reinforcement
- SINTOMIX SM N | Liquid Integral Waterproofing Admixture for Concrete and Mortar
- PP Fibres | Polypropylene Fibres 6, 12 and 18 mm
- SINTOCRETE AntiCorr ST | Rebar Anti-Corrosion Mortar and Bonding Layer
- SINTOCRETE | Fibre-Reinforced Thixotropic R4 Repair Mortar
- SINTOCRETE Basic | Fibre-Reinforced Thixotropic R3 Repair Mortar
- VANDEX SUPER | Penetrating crystalline concrete waterproofing agent
- VANDEX PLUG | Fast-setting sealant for active leaks
- VANDEX UNIMORTAR 1 | Waterproofing and repair mortar
- VANDEX CEMELAST 100 | Two-component elasticised waterproofing mortar
- VANDEX BB 75 | 1C Cementitious Waterproofing Render
- SINTOPLAST | SBR Latex for Mortar Adhesion
- SINMAST S2 Wet on Wet | Epoxy primer for damp substrates
- SINMAST RM 42 | Oily polyurethane protective paint
- SINMAST S2W & S2 WV | Epoxy primer and saturating/bonding resin for FRP fabrics
- SINMAST P 103 | Epoxy Paste for Structural Bonding, Anchoring and Repair
- CERESIT CR 90 Crystaliser | Crystalline waterproofing mortar
- CERESIT CR 166 Flexible 2-K | Flexible cementitious waterproofing compound
- S&P C-Laminate SM & HM | High-Strength Carbon Laminates for Flexural Strengthening
- S&P C-Sheet | Unidirectional Carbon Fibre Fabrics
- SINTECNO SILPORE | Colourless Water and Oil Repellent Impregnation
- fischer FIS EM Plus | Epoxy injection mortar for post-installed rebar and heavy-duty anchoring
Solutions & Applications · Concrete & Marine Environment
On the islands, concrete does not age, it corrodes. Sea salt reaches the reinforcement with water, with salt-laden air, and even with the sand or water that went into the mix. Once chlorides reach the steel, rust expands, the cover spalls and corrosion accelerates. The answer is not one material. It is three decisions: how new concrete is made, how old concrete is repaired, and how whatever has lost strength is reinforced, all with materials that withstand salt.
How close is the sea: XS exposure classes
EN 206 classifies concrete exposed to chlorides from seawater into three classes. The class sets the mix and the reinforcement cover, so it is the first decision in the design:
| Class | Condition | Typical elements | Indicative mix (EN 206, Annex F) |
|---|---|---|---|
| XS1 | Airborne salt, no direct contact with seawater | Seaside houses, balconies, cantilevers, pools near the shore | w/c ≤ 0.50 · C30/37 · ≥ 300 kg/m³ cement |
| XS2 | Permanently submerged in seawater | Foundations of harbour works, submerged parts | w/c ≤ 0.45 · C35/45 · ≥ 320 kg/m³ |
| XS3 | Tidal, splash and spray zones | Quay walls, jetties, seafront walls, boat ramps | w/c ≤ 0.45 · C35/45 · ≥ 340 kg/m³ |
The most aggressive zone is not the submerged one but the splash zone (XS3): the concrete is constantly wetted and dried, salt accumulates and oxygen is plentiful. The values in the table are indicative. The mix and cover are set by the structural design and the national annex.
The most common mistake on the islands is not made in the design, it is made on site: beach sand, water from a brackish well, or concrete "loosened" with water in the truck so it pours more easily. The first two put salt into the concrete from day one. The third raises the water/cement ratio and opens the pores. All three cancel out any admixture that follows.
New construction: dense concrete, deep reinforcement
Chlorides travel through the pores of the concrete. The denser the concrete and the deeper the reinforcement, the more years they need to reach the steel. Four tools, used in combination:
| Tool | What it does | Product |
|---|---|---|
| Superplasticiser | Reduces mixing water by 20–30 % at the same workability, so a lower w/c ratio and denser concrete. Chloride-free. | TECNOS 95 |
| Crystalline integral waterproofing | Crystals close pores and microcracks. No leakage at 13.8 bar, chloride resistance +10 % and sulphate resistance +33 %. Dosage 1–2 % by weight of cement. | VANDEX AM 10 |
| Integral corrosion inhibitor | Contact and migrating action towards the reinforcement, effective in the presence of chlorides. For XS classes to EN 206, 0.8–3.8 kg/m³. | MuCis ad 19/L |
| Polypropylene fibres | Limit plastic shrinkage cracks, the first paths for salt towards the reinforcement. 0.6 kg/m³. | PP Fibres |
In simpler XS1 applications, such as a slab or wall of a house, the liquid integral waterproofer SINTOMIX SM N (0.5 % by weight of cement, chloride-free) with a superplasticiser gives low-porosity concrete with w/c below 0.50.
Reinforcement cover
No admixture replaces cover. In a marine environment Eurocode 2 requires significantly greater cover than for a building inland, increasing from XS1 to XS3. On site this means spacers at the right height and closely spaced, so the reinforcement does not sink during casting. Reinforcement that ends up 1 cm closer to the surface loses years of life.
Curing fresh concrete
Island sun and wind dry fresh concrete before it matures, leaving the surface porous exactly where it needs to be dense. Wet curing for at least 7 days, with wet hessian or sheeting, is not a detail on a seaside project.
Surface protection: the second line of defence
On existing concrete, or new concrete that will be exposed in the splash zone, the surface is protected with a material that cuts the ingress of water and salt without trapping moisture:
| Product | Type | Ideal when |
|---|---|---|
| SINTECNO SILPORE | Colourless water-based silane-siloxane impregnation · no film, keeps the substrate breathable · reduces absorption and chloride salt deposits | Fair-faced concrete, stone and render that must keep their appearance |
| VANDEX SUPER | Penetrating crystalline · positive and negative pressure · protection against seawater · A1 | Tanks, seafront walls, elements in contact with seawater |
| CERESIT CR 90 | Crystalline slurry · seals cracks up to 0.4 mm · limits chlorides | Pools, tanks, basements near the sea |
| VANDEX BB 75 | Cementitious coating R3 · carbonation resistance · corrosion protection of reinforcement | Surface protection and repair in one |
| VANDEX CEMELAST 100 | Flexible 2C · crack bridging 0.5 mm · sD for CO₂ above 50 m | Cracked elements, balconies, cantilevers |
| CERESIT CR 166 | Flexible 2C · crack bridging ≥ 0.5 mm · delays carbonation | Pools, tanks, deformable substrates |
An impregnation forms no layer: it penetrates the pores and makes the surface water-repellent, so rain and salt spray are not absorbed while the concrete keeps "breathing". It is the most discreet protection for fair-faced concrete and stone walls, where a cementitious coating would change the appearance. It is applied to a dry, clean surface, on concrete at least 21 days old, after cracks have been repaired. It does not stop water under pressure, so for elements in contact with seawater a crystalline system is preferred.
Repair: when salt has already reached the reinforcement
Repairing chloride-damaged concrete differs from repairing carbonation damage in one critical point: salt is invisible. The concrete around the rust may look sound and still be full of chlorides. If it stays in place, corrosion restarts right next to the patch.
- Removal: all loose and contaminated concrete, to behind the reinforcement, so that the full perimeter of the bar can be cleaned.
- Cleaning the reinforcement: to bright metal. Where the section has been significantly reduced, reinforcement is supplemented as per the design.
- Corrosion inhibitor: SINTOCRETE AntiCorr ST on the reinforcement, for protection after the section is restored.
- Bonding bridge: SINTOPLAST on old concrete or, on fresh and damp substrates, SINMAST S2 Wet on Wet.
- Section restoration: SINTOCRETE R4 for structural elements, SINTOCRETE Basic R3 or VANDEX UNIMORTAR (R3, 6–12 mm) for non-structural and surface repairs.
- Surface protection: crystalline or flexible cementitious, so that the repair does not become the next door for salt.
The detailed procedure, the warning signs and the difference between R3 and R4 are in the solution on rusted reinforcement. For active seawater leaks in tanks and walls, VANDEX PLUG stops the flow in about 30 seconds and also works underwater.
Strengthening: materials that do not rust
When corrosion has reduced the reinforcement section or the element changes use, repair is not enough and strengthening is needed. By the sea, steel plate strengthening puts exposed steel back into the same corrosive environment. Carbon fibre composites do not corrode and withstand the alkaline environment; where the design calls for a reinforced-concrete jacket, the new reinforcement is protected inside dense concrete with a corrosion inhibitor:
| System | Where | Bonding |
|---|---|---|
| S&P C-Sheet 240 / 640 · unidirectional carbon fibre fabrics | Column confinement, shear strengthening, curved surfaces | SINMAST S2W primer and S2 WV resin (CE to EN 1504-4) |
| S&P C-Laminate SM & HM · carbon laminates | Flexural strengthening of beams and slabs, up to 470 kN (SM) and 554 kN (HM) per laminate | SINMAST P 103 epoxy paste (CE to EN 1504-4) |
| Reinforced-concrete jacket | Columns, beams and walls with heavy section loss | Starter bars in fischer FIS EM Plus · jacket concrete with MuCis ad 19/L and TECNOS 95 |
FRP strengthening always goes on after the repair: on a sound, flat substrate, with the reinforcement already protected. Its design, layers and anchorage are set by a structural design. Jacket starter bars, links and heavy anchors into existing concrete are set in the epoxy injection mortar fischer FIS EM Plus: ETA for rebar connections Ø8–Ø40 mm, seismic categories C1 and C2, use in dry, wet and flooded holes and temperature resistance up to 100 °C. The engineer documents the design with the fischer ETAs and load tables. The mechanisms, the choice of fabric or laminate and the substrate requirements are covered in the solution Strengthening with carbon fibre.
On the islands the real constraint is often not the material but the transport: a truck with wrong or missing materials means days of delay and a second ferry fare. That is why we specify the whole system from the start, admixtures, repair mortars, protection and strengthening, and calculate quantities per element, so everything arrives in one shipment.
Metal elements and floors by the sea
Railings, metal frames and resin floors in seafront areas take the same salt spray. The aliphatic polyurethane coating SINMAST RM 42 has passed 450 hours of salt spray without oxidation and 1,000 hours of artificial UVB ageing without yellowing, and the manufacturer declares it suitable for coastal and marine environments.
Design sequence
- Exposure class: XS1, XS2 or XS3 per element, not one for the whole project.
- Concrete materials: chloride-free aggregates and water, checked on site.
- Mix: w/c ratio, strength class, admixtures as needed.
- Cover: from the design, with spacers that secure it in practice.
- Curing: wet curing of fresh concrete.
- Existing concrete: diagnosis, repair to EN 1504, surface protection.
- Strengthening: FRP where needed, after repair, with a structural design.
- Supply: quantities per element, one shipment to the island.
New Concrete: Admixtures
Concrete Repair
Surface Protection
Structural Strengthening & Anchoring
Related ARGYNET LAB Solutions
Building, repairing or strengthening concrete on an island or by the sea? Send us the element, its distance from the sea and photos of the damage, and we will specify the whole system with quantities for one shipment.
Request a Technical Quote